Remember these tips, and operating the constant temperature and humidity test chamber will be safe and simple.

Source:LINPIN Time:2025-03-21 Category:Industry News


The constant temperature and humidity test chamber is widely used in many industries. To reduce the failure rate and accident rate during use, manufacturers often equip the device with safety protection devices during production. However, we still need to be cautious during specific operations. Keep the following operating procedures in mind to ensure the safety of both the equipment and personnel during use, as well as to guarantee the accuracy of test results.

Electrical safety is a primary concern for many devices, and the constant temperature and humidity test chamber is no exception. The device’s power supply must be grounded to prevent static electricity; the device should use the rated voltage to avoid malfunctions caused by unstable voltage; the power should not be turned on during wiring or installation; external power cords should be neatly placed next to the test hole, avoiding any entanglement.

During the operation of the test chamber, the door should not be opened casually, as the operator may be scalded or frostbitten; high-temperature gas rushing out may also cause a fire. Even if a fire does not occur, it may trigger a fire alarm, causing the machine to malfunction. Frequent opening and closing of the door can damage the compressor, and the evaporator may freeze, preventing normal cooling. Therefore, try to avoid opening the door during the test. If it is necessary to open it, the operator must take safety precautions.

There are also some precautions when placing test items. The items should not exceed 1/3 of the chamber’s volume to prevent blocking the air outlet. If there are many test items, they should be arranged evenly and neatly, avoiding overcrowding to ensure uniform testing.

The location where the device is placed should have minimal dust, good ventilation, and be free of flammable, explosive, highly corrosive, or highly radioactive materials to ensure the safety and lifespan of the device.

When moving the constant temperature and humidity test chamber, handle it gently and slowly. The tilt angle should not exceed 45 degrees, and it should be left for one or two days before use, otherwise, the cooling function may be affected.

During the operation of the machine, it is forbidden to touch electrical components or fans with hands to prevent electric shock or injury.

Operators of the constant temperature and humidity test chamber must undergo professional training and assessment; otherwise, they are not allowed to use the machine to prevent safety accidents.

News Recommendation
Many users often overlook seemingly minor details when operating a high and low temperature alternating test chamber. However, these small oversights can lead to unreliable test results or even safety hazards.
Are you familiar with the role of a thermal shock test chamber? This equipment is commonly used in environmental testing to evaluate the resistance of composite materials or material structures to repeated high and low temperatures, as well as the chemical changes or physical damage caused by thermal expansion and contraction.
You may have heard the recommendation that "a temperature & humidity test chamber should use purified water." But why is that? Can other types of water not be used?
The technical indicators of a high-low temperature test chamber have a systematic and multi-dimensional impact on experimental results. The core lies in whether it can accurately simulate the target environmental conditions and maintain controllability throughout the experimental process.
To establish a standardized and quantifiable daily maintenance process, reduce unexpected downtime, extend the equipment’s economic life cycle, and guarantee the traceability of temperature and humidity values.
Product Recommendation
Telegram WhatsApp Facebook VK LinkedIn