Air-exchange aging test chamber for electrical insulation materials, heat resistance test, electronic parts and components, plasticized products of the air-exchange aging test, assessment and judgment of its storage and use in high-temperature ambient conditions of adaptability, the specimen in the simulation of high temperatures and atmospheric pressure in the air after the aging of the determination of its performance and performance to be compared with the performance of the non-aging samples.

Service Hotline

4000-662-888
Product Features
Product Parameter
Model Studio Size  (D*W*H)mm Dimension(D*W*H)mm
LRHS-101-NHQ 450×450×500 730×1180×1480
LRHS-225-NHQ 500×600×750 780×1330×1730
LRHS-504-NHQ 700×800×900 1120×1430×1880
LRHS-800-NHQ 800×1000×1000 1120×1730×1980
LRHS-1000-NHQ 1000×1000×1000 1320×1730×1980
temperature range RT+10℃~200℃/ RT+10℃~300℃
Temperature uniformity ≤2%℃ (at no load)
Temperature fluctuation ±0.5℃ (at no load)
heating rate 1.0~3.0℃/min
air exchange RT+10℃~200℃ 10-200次/H
201℃~300℃ 10-150次/H
air intake and exhaust Scale Indicator, Adjustable Flip Flop
a turntable for testing specimens Two-tier stainless steel rotating rack Speed: 1~5r/min
(Customized sample racks are also available upon request)
Outer case material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam + fiberglass
Other viewing window 210×275mm or 395×395mm (effective field of view)
(No observation window for test chambers above 200°C)
Temperature Controller Korea Sangwon ST590 Meter
temperature sensor PT100 platinum resistance temperature measurement body
standard configuration One set of carousel type sample holder
security protection Control line fuse, motor overheating, equipment timing, over-temperature, under-phase/reverse-phase of the whole machine
Leakage protection, power distribution control cabinet open power failure protection, automatic shutdown after fault alarms
Supply Voltage AC220V±10% 50Hz 或AC380V±10% 50Hz
Power 4.3kW/6.5kW/7.5kW/9.5kW/9.5kW
operating environment 5℃~+35℃ ≤85% RH
Note:
1、according to the user’s specific requirements for customized non-standard walk-in gas-exchange aging test chamber
2、Can be customized according to the specific requirements of the user non-standard air-exchange aging test chamber etc
3、This technical information, if there is any change without prior notice

 

Product Recommendation
Industry News
In the market, thermal shock test chambers come in two types: two-chamber and three-chamber designs. Some customers may wonder which type to choose—can they opt for a three-chamber model?
It is crucial to operate a high and low temperature test chamber correctly.
Although the thermal shock test chamber also simulates different natural temperatures to test the weather resistance of samples