| Model | Studio Size (D*W*H)mm | Dimension(D*W*H)mm | |
| LRHS-225-WSZ | 500×600×750 | Subject to contractual three-view | |
| LRHS-1000-WSZ | 1000×1000×1000 | ||
| LRHS-2000-WSZ | 1000×2000×1000 | ||
| LRHS-8000-WSZ | 2000×2000×2000 | ||
| temperature range | -60℃~150℃ | ||||||
| Temperature uniformity | ≤2℃ (at no load) | ||||||
| Temperature fluctuation | ±0.5℃(at no load) | ||||||
| Time Setting Range | 1~60000M | ||||||
| Humidity range | 20%~98% RH | ||||||
| Humidity uniformity | +2% -3% RH | ||||||
| Humidity fluctuations | ±2% | ||||||
| heating rate | 1.0~3.0℃/min | ||||||
| cooling rate | 0.7~1.0℃/min | ||||||
| Lifting platform | Lifting platform method to adjust the height of the test chamber | ||||||
| viewing window | 210 x 275mm or 395 x 395mm (effective field of view) | ||||||
| sinusoidal thrust | ≥2200kN | ||||||
| random thrust | ≥2200kN | ||||||
| Impact thrust (6ms) | ≥4400kN | ||||||
| frequency range | DC~3000Hz | ||||||
| sustained displacement | 45mm(p-p) | ||||||
| shock displacement | 45mm(p-p) | ||||||
| Maximum speed | 1.5~2.5m/s | ||||||
| maximum acceleration | 950m/s² | ||||||
| First order resonant frequency | 2600Hz | ||||||
| Allowable eccentricity moment | >500N×m | ||||||
| load junction | 16 connections | ||||||
| Axial vibration isolation frequency | <3Hz | ||||||
| Maximum load | 300kg | ||||||
| Countertop Size | 600mm×600mm | ||||||
| Maximum load | 300kg | ||||||
| Outer case material | High quality A3 steel plate electrostatic spraying | ||||||
| Inner box material | Imported high-grade stainless steel SUS304 | ||||||
| Insulation material | Rigid polyurethane foam + fiberglass | ||||||
| Temperature Controller | Japan’s original imported “UEC” brand temperature meter | ||||||
| temperature sensor | PT100 platinum resistance temperature measurement body | ||||||
| Cooling method | Two-machine cascade refrigeration | ||||||
| Compressor | Tycon (France) / BITZER (Germany) | ||||||
| security protection | Compressor overpressure overload, over temperature, fan motor overheating, leakage protection Machine under-phase/reverse-phase, test timing, overload and short circuit protection. |
||||||
| Supply Voltage | AC380V±10% 50Hz | ||||||
| Power | 24.0kW/48.0kW/60.0kW/85.0kW | ||||||
| operating environment | 5℃~+28℃ ≤85% RH | ||||||
| Note: 1、 the test data are used in the ambient temperature of 25 ℃ and well ventilated conditions measured 2、Can be customized according to the specific requirements of the user non-standard three integrated test chamber etc 3、This technical information, subject to change without notice |
|||||||