High-temperature aging room old refining screening using pure resistance heat 100KW, winter using outdoor fresh air ventilation temperature control, summer using cold water plate for temperature control of sophisticated screening process equipment, for high-performance electronic products simulation of a high-temperature, harsh environment testing equipment, so that customers quickly find out the problem, solve the problem to provide an effective means to fully improve the customer's production efficiency and product quality.

Service Hotline

4000-662-888
Product Features
Product Parameter
Model Studio Size  (D*W*H)mm Dimension(D*W*H)mm
LRHS-96M³ 12000×4000×2000 roughly 12200×4200×2600
Temperature range RT+5℃~60℃
Temperature fluctuation ≤±0.5℃(unladen)
Temperature uniformity ≤2.0℃(unladen)
Temperature deviation ±2.0℃
Heating rate 0.7~1.0℃/min
Other Equipped with fresh air system
Outer box material High-quality library board
Inner box material Imported high-grade stainless steel SUS304
Insulation Environmental protection rock wool board
Viewing window Conductive insulating glass
Temperature Controller Imported “UMC” brand temperature and humidity meter
Temperature sensor PT100 Platinum resistance thermometer
Heating mode Electrically heated Nitro alloy
Safety Fan, motor, pump overcurrent overload protection, limit, undervoltage, short circuit, phase loss, over temperature, leakage protection
Supply Voltage AC380V±10% 50Hz
Power 52KW
Note:
1、 the above data are in the use of ambient temperature of 25 ℃ and well ventilated conditions measured
2、Can be customized according to the user’s specific test requirements of ice-covered test chamber, ice-covered test chamber, etc.
3、This technical information, subject to change without notice

 

Product Recommendation
Industry News
During the operation of a temperature and humidity test chamber, some abnormal situations may occur, such as excessive overheating of the condenser tube.
Maintaining a constant temperature and humidity test chamber involves several critical factors. Today, we’ll break them down for you.
Cold and hot shock test chambers utilize high-temperature and low-temperature zones during testing. In the testing process, two-box models involve placing the test product in high and low-temperature zones for cyclic exposure, while three-box models involve blowing high- and low-temperature gases onto the product alternately.