Key Considerations for Operating a Formaldehyde Test Chamber‌

Source:LINPIN Time:2025-07-11 Category:Industry News

Improper operation of a formaldehyde test chamber may lead to equipment failure. To help users avoid operational errors, here are some important points to keep in mind when using the device.

formaldehyde test chamber

‌Pre-Test Inspection and Preparation‌

Before testing, thoroughly inspect the formaldehyde test chamber to ensure all components are intact.
Prepare the device properly, such as filling the water tanks (add water to the high and low tanks to the specified levels, then tighten the water valve to prevent air leakage).
‌Powering On and System Initialization‌

After inspection, place the test sample inside the chamber as required.
Connect the power supply and turn on the corresponding switches.
Wait 15 seconds for the touchscreen to display the operating system (if no alarm appears, the water level is normal; otherwise, add water until the alarm stops).
Press the start button to begin the test.
‌Adjusting Gas Flow and Monitoring Water Level‌

Adjust the gas flow meter to ‌1 m³/h‌.
Observe the water level display—during simultaneous operation of the water pump and air pump, the water level should remain stable, fluctuating between the medium and high water level indicators.
‌Checking Fan Operation‌

Ensure the internal fan is running smoothly, as normal fan operation indicates the device is functioning correctly.
‌Temperature Control During Testing‌

If the ambient temperature exceeds ‌30°C‌, use air conditioning to cool the environment and prevent test result deviations (monitor relative humidity to avoid interference).
If the temperature drops below ‌10°C‌, use heating equipment to adjust conditions.
These are the key operational considerations for formaldehyde test chambers. Since many details can affect testing, users should troubleshoot issues based on actual conditions. As the saying goes, ‌”Details determine success or failure”‌—paying attention to small factors ensures accurate and reliable test results.

 

News Recommendation
Thermal vacuum testing is a type of test that verifies the performance and functionality of spacecraft and its components under vacuum and specific temperature conditions.
Any sand and dust test chamber may encounter malfunctions during use. Today, we will share solutions for the following 4 common faults.
As we all know, UV aging test chambers are composed of many components. In fact, there are also some auxiliary accessories that may be used during the operation of the equipment. The use of these accessories can make the testing process smoother. Today, I would like to introduce several such accessories to you.
To ensure the accuracy of the rain test chamber results, the correct operation of the equipment is essential. So, how should the device be operated? What details need attention during the operation process?
Beneath its tough exterior, the low-temperature test chamber has a gentle heart. Why do we say that?
Product Recommendation
Telegram WhatsApp Facebook VK LinkedIn