Key Considerations for Operating a Formaldehyde Test Chamber‌

Source:LINPIN Time:2025-07-11 Category:Industry News

Improper operation of a formaldehyde test chamber may lead to equipment failure. To help users avoid operational errors, here are some important points to keep in mind when using the device.

formaldehyde test chamber

‌Pre-Test Inspection and Preparation‌

Before testing, thoroughly inspect the formaldehyde test chamber to ensure all components are intact.
Prepare the device properly, such as filling the water tanks (add water to the high and low tanks to the specified levels, then tighten the water valve to prevent air leakage).
‌Powering On and System Initialization‌

After inspection, place the test sample inside the chamber as required.
Connect the power supply and turn on the corresponding switches.
Wait 15 seconds for the touchscreen to display the operating system (if no alarm appears, the water level is normal; otherwise, add water until the alarm stops).
Press the start button to begin the test.
‌Adjusting Gas Flow and Monitoring Water Level‌

Adjust the gas flow meter to ‌1 m³/h‌.
Observe the water level display—during simultaneous operation of the water pump and air pump, the water level should remain stable, fluctuating between the medium and high water level indicators.
‌Checking Fan Operation‌

Ensure the internal fan is running smoothly, as normal fan operation indicates the device is functioning correctly.
‌Temperature Control During Testing‌

If the ambient temperature exceeds ‌30°C‌, use air conditioning to cool the environment and prevent test result deviations (monitor relative humidity to avoid interference).
If the temperature drops below ‌10°C‌, use heating equipment to adjust conditions.
These are the key operational considerations for formaldehyde test chambers. Since many details can affect testing, users should troubleshoot issues based on actual conditions. As the saying goes, ‌”Details determine success or failure”‌—paying attention to small factors ensures accurate and reliable test results.

 

News Recommendation
Previously, we have discussed many technical aspects of temperature cycling test chambers. Today, we will share methods for detecting leaks in these chambers. Specifically, there are four main approaches to check for leaks.
Temperature is the most fundamental—and most brutal—physical parameter influencing the reliability of materials, components and complete systems. GB/T 2423.1, GB/T 2423.2, GJB 150.3A, GJB 150.4A, DO-160 Section 4/5, IEC 60068-2-1/-2 and MIL-STD-810H all quantify requirements for temperature slew rate, dwell time, heat load and measurement uncertainty.
If the temperature exceeds the set value during testing in a constant temperature and humidity test chamber, how should we resolve it? Are there any emergency response measures?
The high-low temperature test chamber is the cornerstone of environmental reliability testing. Its cooling rate dictates test duration and data validity. Field data from 500+ chambers over ten years show that “slow cooling” accounts for 38 % of all malfunctions, second only to “no cooling”.
In the process of enterprise production and quality inspection, the salt spray test chamber plays a crucial role. Some enterprises use the salt spray test chamber with a high frequency. Under long-term and high-load operation, it is inevitable that the equipment will encounter faults.
Product Recommendation
Telegram WhatsApp Facebook VK LinkedIn