Why Does the High – Low Temperature Test Chamber Sound the Alarm?

Source:LINPIN Time:2025-03-17 Category:Industry News

Today, the editor of Linpin Instruments will guide us in troubleshooting the alarm of the high – low temperature test chamber.
The alarm might be due to issues in the centrifugal fan section, such as over – temperature or over – current. For instance, an overheated magnetic coil or excessive current beyond the control value can trigger an alarm and shutdown.

High and Low Temperature Test Chamber
Temperature system problems could also be the culprit, like specimen overheating protection or cabinet overheating. If the specimen area’s temperature exceeds the control board’s set protection temperature, or the cabinet’s temperature goes beyond the control panel’s setting, the chamber will shut down and alarm.
The refrigeration machine might be another source of the alarm. Scenarios include an overheated magnetic coil of the refrigeration compressor, abnormal power supply, excessively high refrigerant working pressure, low cooling water level in the circulation system, or power phase – break/phase – sequence issues. For example, an overheated magnetic coil or abnormal power supply can cause an over – temperature alarm and shutdown, while high refrigerant pressure results in an over – pressure alarm.
When the alarm sounds, promptly investigate the cause. If the problem persists after initial handling, contact the manufacturer’s after – sales personnel. Linpin Instruments, as a professional test chamber manufacturer, offers technical support. Call 400 – 066 – 2888 for technical consultation.

News Recommendation
With the rapid development of industrial production, temperature and humidity test chambers have become essential equipment for simulating external climatic conditions.
Cold and hot shock test chambers are widely used in various industries such as automotive parts, communications, plastics, aerospace, chemical materials, LED, and electronic testing.
Are there any standards for the aging test chamber before it leaves the factory?
If the high and low temperature humidity test chamber is used frequently and for a long time, the water in the equipment's water tank may not be sufficient to complete the test.
Some customers report that their sand and dust test chambers are not operating efficiently and have reached a bottleneck.
Product Recommendation
Telegram WhatsApp Facebook VK LinkedIn