Why Does the High – Low Temperature Test Chamber Sound the Alarm?

Source:LINPIN Time:2025-03-17 Category:Industry News

Today, the editor of Linpin Instruments will guide us in troubleshooting the alarm of the high – low temperature test chamber.
The alarm might be due to issues in the centrifugal fan section, such as over – temperature or over – current. For instance, an overheated magnetic coil or excessive current beyond the control value can trigger an alarm and shutdown.

High and Low Temperature Test Chamber
Temperature system problems could also be the culprit, like specimen overheating protection or cabinet overheating. If the specimen area’s temperature exceeds the control board’s set protection temperature, or the cabinet’s temperature goes beyond the control panel’s setting, the chamber will shut down and alarm.
The refrigeration machine might be another source of the alarm. Scenarios include an overheated magnetic coil of the refrigeration compressor, abnormal power supply, excessively high refrigerant working pressure, low cooling water level in the circulation system, or power phase – break/phase – sequence issues. For example, an overheated magnetic coil or abnormal power supply can cause an over – temperature alarm and shutdown, while high refrigerant pressure results in an over – pressure alarm.
When the alarm sounds, promptly investigate the cause. If the problem persists after initial handling, contact the manufacturer’s after – sales personnel. Linpin Instruments, as a professional test chamber manufacturer, offers technical support. Call 400 – 066 – 2888 for technical consultation.

News Recommendation
The uniformity of a thermal shock test chamber directly affects the test results, so it is crucial to maintain optimal uniformity.
The technical indicators of a high-low temperature test chamber have a systematic and multi-dimensional impact on experimental results. The core lies in whether it can accurately simulate the target environmental conditions and maintain controllability throughout the experimental process.
In the field of quality inspection and reliability testing, constant temperature and humidity test chambers and high and low temperature test chambers are two commonly used environmental simulation devices, each with unique functions and application scenarios.
If the temperature recovery time falls outside the specified range, it can affect the test results of the thermal shock chamber. To routinely test the temperature recovery time of the equipment, you can follow the steps below.
High-low temperature test chambers are precision instruments that must be operated strictly by trained personnel following standard procedures and subjected to regular preventive maintenance. Any operational error or neglected upkeep can trigger a variety of faults, delaying test schedules. The equipment integrates refrigeration, heating, humidification, electrical control and other subsystems. Effective troubleshooting therefore requires a holistic “whole-machine mindset” to pinpoint and solve problems quickly.
Product Recommendation
Telegram WhatsApp Facebook VK LinkedIn