Search for the product you are looking for
High and Low Temperature Humidity Test Chamber

High and Low Temperature Humidity Test Chamber

Product Introduction
High and low temperature humidity test chamber is aviation, automotive, home appliances, scientific research and other fields of essential test equipment for testing and determining electrical, electronic and other products and materials for high temperature, low temperature, alternating humidity and heat or constant test temperature environment after the change of parameters and performance.

Service Hotline

4000-662-888
Product Features
Product Parameter
Model Studio Size  (D*W*H)mm Dimension(D*W*H)mm
LRHS-101B-LS 450×450×500 1160×1000×1610
LRHS-225B-LS 500×600×750 1210×1150×1870
LRHS-504B-LS 700×800×900 1260×1340×2070
LRHS-800B-LS 800×1000×1000 1370×1550×2170
LRHS-1000B-LS 1000×1000×1000 1560×1550×2170
temperature range A:-20℃~150℃     B:-40℃~150℃
C:-60℃~150℃     D:-70℃~150℃
Temperature uniformity ≤2℃(at no load)
Temperature fluctuation ±0.5℃(at no load)
Time Setting Range 1~9999H
Humidity range 20%~98% RH
Humidity uniformity +2% -3% RH
Humidity fluctuation ±2%
heating rate 1.0~3.0℃/min
cooling rate 0.7~1.0℃/min
test hole Mounted on the left side of the machine for use with external test power or signal cables
viewing window 210 x 275mm or 395 x 395mm (effective field of view)
Outer case material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam + fiberglass
Temperature Controller Korea Saintyear TEMI300
temperature sensor PT100 platinum resistance temperature measurement body
Cooling method Single or double cascade refrigeration
Compressor Taikang, France
standard configuration 1 roll of wet bulb gauze, 2 sample racks, with condensate catch pan and drain out of the box
security protection Compressor overpressure overload, fan motor overheating, the overall equipment under phase / reverse phase
Over-temperature, overall equipment timing, leakage protection, overload and short-circuit protection
Supply Voltage AC380V±10% 50Hz
Power (A)3.5kW/4.0kW/6.0kW/8.0kW/9.0kW
(B)4.0kW/4.5kW/7.5kW/9.0kW/10.5kW
(C)4.5kW/6.5kW/9.0kW/13.0kW/13.0kW
operating environment 5℃~+28℃ ≤85% RH
Note:
1、the above data are in the use of ambient temperature of 25 ℃ and well ventilated conditions measured
2、Can be customized according to the specific requirements of the user non-standard high and low temperature humidity test chamber etc
3、This technical information, subject to change without notice

 

Product Recommendation
Industry News
Salt spray test chambers evaluate the corrosion resistance of samples by exposing them to a corrosive salt mist, allowing comparison with other products. These tests can be categorized into three types
Previously, we have discussed many technical aspects of temperature cycling test chambers. Today, we will share methods for detecting leaks in these chambers. Specifically, there are four main approaches to check for leaks.
its service life. Today, let’s explore the maintenance and care of high-low temperature alternating humidity test chambers.
Telegram WhatsApp Facebook VK LinkedIn