Tips: Emergency Response Plan for Temperature Overshoot in Constant Temperature and Humidity Test Chambers

Source:LINPIN Time:2025-05-28 Category:Industry News

If the temperature exceeds the set value during testing in a constant temperature and humidity test chamber, how should we resolve it? Are there any emergency response measures?

constant temperature and humidity test chamber

As we all know, temperature overshoot in a constant temperature and humidity test chamber can affect the accuracy of test results. Therefore, such situations require prompt attention. Temperature overshoot refers to the temperature exceeding the allowable range. However, some degree of overshoot is permissible under certain conditions:

If the test point allows for a certain temperature range, the overshoot may vary within approximately 2°C.
If the temperature exceeds a specified stability limit, the overshoot should not exceed 2% of the test point.
For example, within 0–100°C, the overshoot should not exceed 2°C.
For temperatures above 100°C, the overshoot should not exceed 2% of the test point.
If the temperature overshoot falls within these ranges, it is considered acceptable. However, if the overshoot exceeds these limits, it is necessary to investigate whether a malfunction has occurred. In such cases, contact the manufacturer’s technical personnel for calibration or seek assistance from a professional service provider.

After purchasing the equipment, users should familiarize themselves with the product specifications of the constant temperature and humidity test chamber. This will help operators determine whether the issue is within controllable limits and take appropriate corrective measures. Our company not only provides high-quality testing equipment but also offers continuous after-sales support to promptly troubleshoot any issues.

Generally, the control system is the “brain” of a constant temperature and humidity test chamber, determining critical parameters such as heating rate and accuracy. Many modern devices use PID controllers. Our company’s constant temperature test equipment features an upgraded control system with high precision and advanced automation.

Currently, we offer a variety of chamber sizes to meet different testing requirements. Domestic and international customers can select the most suitable model based on their material characteristics. We welcome visits to our facility for on-site inspections and equipment purchases. Our company is committed to providing environmental testing solutions and high-performance equipment for the industry.

News Recommendation
High-low temperature test chambers are equipped with separators, which come in different types.
The refrigeration compressor is one of the key components affecting the test results of a high and low temperature test chamber. To ensure smooth operation, proper maintenance of the compressor is essential. During daily operation, the following actions must be avoided
Are you familiar with the role of a thermal shock test chamber? This equipment is commonly used in environmental testing to evaluate the resistance of composite materials or material structures to repeated high and low temperatures, as well as the chemical changes or physical damage caused by thermal expansion and contraction.
It is crucial to operate a high and low temperature test chamber correctly.
High and low temperature humidity test chambers require electricity to operate, which inevitably leads to energy consumption. Saving electricity not only reduces energy waste but also lowers the operational costs of the equipment.