Reminder: Things You Should Never Do to the Compressor of a High and Low Temperature Test Chamber

Source:LINPIN Time:2025-04-08 Category:Industry News

The refrigeration compressor is one of the key components affecting the test results of a high and low temperature test chamber. To ensure smooth operation, proper maintenance of the compressor is essential. During daily operation, the following actions must be avoided:

Operate the Test Chamber Correctly

Never perform water pressure tests using nitrogen without a valve.
Never use oxygen for water pressure tests, as such improper operations may cause explosions.
Always follow the correct operating procedures to ensure safety.
Avoid Using Alcohol for Moisture Removal

While a drying filter can be used to reduce moisture in the system during compressor operation, ethanol must never be used for dehumidification, as it can severely damage the motor windings and cause burnout.
If carbon tetrachloride is used for drying, it must be replaced within 24 hours; otherwise, reabsorption of moisture may form a sticky substance that can enter the compressor and damage components.


Installing a breather filter can help prevent contaminants from entering the compressor.
Prevent Electrical Short Circuits

Use insulating tape to seal insulation layers, ensuring that critical wiring and thermal protection terminals inside the compressor do not loosen or accumulate excessive frost, which could lead to short circuits.
Never close the exhaust valve while the compressor is running, as this may cause severe damage.
Refrigerant Charging Precautions

Refrigerant must always be charged into the system through the high-pressure valve.
Never overcharge refrigerant through the suction valve during compressor operation, as this may cause liquid slugging (hydraulic shock), damaging the compressor.
Avoid Hazardous Environments and Low-Quality Refrigerants

The compressor must never be used in environments containing flammable, explosive, or corrosive substances.
Never use counterfeit refrigerants, such as low-quality R22 (difluorochloromethane) mixed with 30% methyl chloride (chloromethane).
Methyl chloride is highly corrosive to aluminum, magnesium, and zinc, leading to irreversible damage to the compressor and internal components. Always use genuine refrigerants to avoid safety risks.
By following these guidelines, you can ensure the longevity and reliable performance of your high and low temperature test chamber’s compressor. Always prioritize safety and proper maintenance to prevent avoidable failures.

News Recommendation
Regularly, staff should master some troubleshooting and handling methods for high and low temperature alternating test chambers. If the equipment exhibits unstable low temperatures, what causes this phenomenon, and how should we address these faults?
The constant temperature and humidity test chamber is widely used in many industries. To reduce the failure rate and accident rate during use
If the temperature exceeds the set value during testing in a constant temperature and humidity test chamber, how should we resolve it? Are there any emergency response measures?
There are significant differences between walk-in sand and dust test chamber and military standard sand and dust test chamber in many aspects.
High and low temperature test chambers are designed to simulate natural climatic conditions to test the high- and low-temperature endurance of products or materials under alternating temperature changes.