Remember these tips, and operating the constant temperature and humidity test chamber will be safe and simple.

Source:LINPIN Time:2025-03-21 Category:Industry News


The constant temperature and humidity test chamber is widely used in many industries. To reduce the failure rate and accident rate during use, manufacturers often equip the device with safety protection devices during production. However, we still need to be cautious during specific operations. Keep the following operating procedures in mind to ensure the safety of both the equipment and personnel during use, as well as to guarantee the accuracy of test results.

Electrical safety is a primary concern for many devices, and the constant temperature and humidity test chamber is no exception. The device’s power supply must be grounded to prevent static electricity; the device should use the rated voltage to avoid malfunctions caused by unstable voltage; the power should not be turned on during wiring or installation; external power cords should be neatly placed next to the test hole, avoiding any entanglement.

During the operation of the test chamber, the door should not be opened casually, as the operator may be scalded or frostbitten; high-temperature gas rushing out may also cause a fire. Even if a fire does not occur, it may trigger a fire alarm, causing the machine to malfunction. Frequent opening and closing of the door can damage the compressor, and the evaporator may freeze, preventing normal cooling. Therefore, try to avoid opening the door during the test. If it is necessary to open it, the operator must take safety precautions.

There are also some precautions when placing test items. The items should not exceed 1/3 of the chamber’s volume to prevent blocking the air outlet. If there are many test items, they should be arranged evenly and neatly, avoiding overcrowding to ensure uniform testing.

The location where the device is placed should have minimal dust, good ventilation, and be free of flammable, explosive, highly corrosive, or highly radioactive materials to ensure the safety and lifespan of the device.

When moving the constant temperature and humidity test chamber, handle it gently and slowly. The tilt angle should not exceed 45 degrees, and it should be left for one or two days before use, otherwise, the cooling function may be affected.

During the operation of the machine, it is forbidden to touch electrical components or fans with hands to prevent electric shock or injury.

Operators of the constant temperature and humidity test chamber must undergo professional training and assessment; otherwise, they are not allowed to use the machine to prevent safety accidents.

News Recommendation
When you need to test materials under alternating high-low temperature and humidity conditions, purchasing a temperature & humidity test chamber is essential. But how do you go from zero to owning the right equipment? Just follow these 6 steps.
Rain test chamber is a test instrument to test whether the waterproof is good, the figure of this equipment can be said to be everywhere, applied in various places. Small to our usual use of cell phones, flashlights and other lighting apparatus; large to the aerospace industry, lighting systems, signaling device testing and so on. Waterproof has always been a lot of industry can not get around a topic, a lot of equipment once the rain and other wet, its service life will be greatly reduced, this equipment in the waterproof performance test link plays a vital role.
Low-temperature test chambers are primarily used to evaluate the storage capabilities and environmental adaptability of products and materials from industries such as electronics, electrical engineering, automotive, and home appliances under extremely low-temperature climatic conditions.
The salt spray test chamber is an essential testing device for evaluating the corrosion resistance of various materials. Depending on the material or product being tested, key parameters such as temperature, humidity, pH value, and solvent composition may vary.
Previously, we introduced some common problems with high and low temperature test chambers. Today, we will discuss the issue of slow cooling in the test equipment, which may be caused by malfunctions in the refrigeration system.
Product Recommendation