Search for the product you are looking for
研发中心

News

Slide down

List of Precautions to Note During the Use of a Rain Test Chamber

Source:LINPIN Time:2025-05-20 Category:Industry News

To ensure relatively accurate test results from a rain test chamber, there are several key points to pay attention to. Below, we outline these precautions for your reference.

Pre-Test Preparations Must Be Thorough:

Inspect all components and accessories.
Ensure there are no impurities in the water tank and that it is filled to the required level. Note: The water used must be purified or filtered.
Place the sample securely inside the chamber, ensuring it is not loose.
Close the drainage valve and set the flow control valve to its maximum position.
Before starting the pressure pump for the first time, bleed the air from it by loosening the pump’s vent hole. Then, open the pump’s water inlet valve until water flows out of the vent before tightening the cap.

rain test chamber
Setting the Test Duration:

After connecting the power, set the test duration. A setting of “0” means the test will not run. The duration can be set to any value between 0 and 100 hours.
Once the set time is reached, the test will automatically stop. Alternatively, you can manually stop the test by pressing the stop button during operation.
Adjusting the Flow Control Valve During Operation:

Adjust the flow control valve so that the red float in the flow meter reaches the desired flow rate position.
Precautions for Components During Operation:

Do not start the water pump when there is no water in the tank, as this may damage the motor and piping.
The nozzle must be fixed or held firmly by hand to prevent it from swinging due to high pressure when the device is turned on.
Post-Test Procedures:

After completing the test, turn off the power and analyze the sample’s performance and parameters based on relevant data.
Clean any debris inside and outside the chamber, and conduct a thorough inspection to ensure the equipment remains in good condition.
While reading this article, have you noted all these precautions for using a rain test chamber? If you’ve missed any, be sure to incorporate them in your next operation. Doing so will help the device perform tests more effectively. For more information on testing equipment, stay tuned to our website.

News Recommendation
Conducting tests on specimens using sand and dust test chamber equipment incurs certain costs. One of the most critical factors influencing the cost of specimen testing is the selection of the testing equipment. How does the specific equipment affect operating costs?
The salt spray test chamber is essential for corrosion resistance testing of metal products, stone products, coatings, and more. However, without regular cleaning and maintenance, dust buildup, component wear, rust, and other issues can lead to equipment failure, disrupting production progress.
One of Linpin's standout products, the high-low temperature test chamber, excels with its impressive heating rate (1.0~3.0℃/min), cooling rate (0.7~1.0℃/min), and thoughtful multi-segment temperature range settings (A: -20℃ to 150℃; B: -40℃ to 150℃; C: -60℃ to 150℃; D: -70℃ to 150℃).
A UV aging test chamber is a device that artificially simulates the UV environment and high-temperature conditions found in nature to conduct light-fastness tests on non-metallic products and obtain their light-fastness results.
When a cold and hot shock test chamber, which has been running smoothly, suddenly stops cooling, what could be the reason?
Product Recommendation
Telegram WhatsApp Facebook VK LinkedIn