Are You Maintaining Your Constant Temperature and Humidity Test Chamber Correctly?

Source:LINPIN Time:2025-03-14 Category:Industry News

If a constant temperature and humidity test chamber malfunctions due to improper operation or lack of maintenance, it will not only affect the progress of work but also incur costs much higher than those of regular maintenance. This highlights the critical importance of daily maintenance for this equipment. But how exactly should you maintain it? Are you doing it correctly?
The most basic maintenance for a constant temperature and humidity test chamber involves checking for any loosening, rusting, missing parts, instability, dents, or cracks in screws, components, wiring, and panels. You should also inspect gaskets, plugs, and seals for signs of aging and address any issues promptly.
The compressor is a vital and expensive component of the instrument, so maintaining it properly is essential. The compressor requires a stable voltage to operate, as fluctuations can easily cause damage. Therefore, a voltage stabilizer should be installed on the test chamber. Additionally, the compressor should not be switched on and off frequently; there should be a gap of at least 15 minutes between each operation.
If the motor or rotary reducer of the equipment operates unevenly or produces noise, you should remove any debris and apply lubricating oil.
Periodically check the pump, piping, and drainage tank in the circulation system for leaks or sediment buildup, and carry out repairs and cleaning as needed.
If the constant temperature and humidity test chamber is not going to be used for an extended period, you should disconnect the power supply, clean and dry the interior of the chamber, and store it in a dry, ventilated place away from direct sunlight. Do not cover the equipment with plastic to prevent dust accumulation, as this can cause component rust. Even if the equipment is not in use, it is advisable to power it on once a month for about an hour to protect the compressor.
To prevent rusting of components, regularly wipe them with oil. When adding water to the equipment, avoid using tap water with high impurities; instead, use purified water or distilled water.
Regular maintenance using the correct methods can protect and extend the lifespan of a constant temperature and humidity test chamber. Staff should remember these practices and accumulate experience through continuous maintenance to ensure the equipment performs optimally.

News Recommendation
There are significant differences between walk-in sand and dust test chamber and military standard sand and dust test chamber in many aspects.
A salt spray test chamber is an accelerated corrosion environmental testing device. The primary causes of metal corrosion include oxygen, salt particles, pollutants in the air, as well as changes in temperature and humidity.
Now that winter has arrived and snow has begun to fall in some areas, how can companies properly maintain their UV aging test chambers while in use?
This equipment provides an accelerated testing method to evaluate the corrosive effects of sulfur dioxide-polluted atmospheres on contact points and connectors, particularly suitable for comparative testing.
The refrigeration compressor is one of the core components of a high/low-temperature test chamber, and its selection is closely related to the test results. In fact, semi-hermetic compressors are commonly used in these chambers. Why is this the case? Today, we will explore the three main reasons.
Product Recommendation
Telegram WhatsApp Facebook VK LinkedIn